TM 5-5420-227-24
LEFT CUPOLA QUADRANT REPLACEMENT (Sheet 1 of 2)
TOOLS:
3/4 in. socket with 3/4 in. drive
1-5/16 in. socket with 3/4 in. drive
Lifting device (500 lbs capacity)
Put t y knife
SUPPLIES:
PERSONNEL:
Three
REFERENCE:
PRELIMINARY PROCEDURES:
Remove cupola cover safety latch (page 3-17)
REMOVAL:
1.
Using 3/4 inch socket, remove seven screws
(A).
2.
Using 1-5/16 inch socket, remove six screws
(B).
Attach lifting device to handle (C).
3.
4.
Using lifting device,' lift quadrant
(D) slowly from vehicle.
Have technician operating lifting device slowly lower quadrant (D) to desired location.
5.
Remove lifting device from handle (C).
6.
7.
Using putty knife, remove old sealant from mating surfaces of vehicle and quadrant.
Go on to Sheet 2
TA170261
3-33