TM 5-5420-228-24
SIMPSON 160
1.
PLUG BLACK LEAD INTO -COM JACK.
(E.G. TO MEASURE 24 VOLTS DC, TURN SELECTOR TO VDC 50.
TO MEASURE LESS THAN 10 VOLTS, TURN SELECTOR TO VDC
10. TO MEASURE LESS THAN 2.5 VOLTS, TURN SELECTOR TO
2.
PLUG RED LEAD INTO +JACK.
VDC 2.5.)
IF YOU ARE UNSURE OF VOLTAGE TO BE MEASURED, TURN
3.
SET POLARITY REVERSING SWITCH TO DIR/+DC POSITION.
SELECTOR TO VDC 1000 FOR FIRST READING, THEN REDUCE
RANGE AS SHOWN ABOVE FOR THE AN/URM-105 MULTIMETER.
4.
TURN SELECTOR SWITCH TO PROPER VDC RANGE FOR VOLTAGE
USING YOUR RANGES, NEXT READING WOULD BE MADE IN
YOU WISH TO MEASURE.
VDC 50A POSITION.
TA251316
DC voltage measurement setup.
2-16