TM 5-5420-278-100058 000058 00-3MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTIONOperator’s Mechanical Troubleshooting (Contd)4. INNER OR OUTER PONTON LEAKINGStep 1. Check for loose, damaged, or missing bilge plugs and bilge plug seals.a. Tighten loose bilge plugs (WP 0010 00 and WP 0011 00).b. If bilge plugs and seals are damaged or missing, notify unit maintenance.c. If bilge plug retaining cable is damaged, notify unit maintenance.Step 2. Inspect ponton for structural damage such as cracks, broken welds,or holes.a. If visible structural damage is found, notify unit maintenance.b. If no visible structural damage can be found and leaking persists,notify unit maintenance.END OF TESTING5. OUTER PONTON LOCK WILL NOT ENGAGE OR HOLD WHEN ENGAGED(INTERIOR BAY ONLY)Step 1. Check for bent or damaged outer ponton lock/release lever, receiverplate, or turnbuckle.If bent or damaged, notify unit maintenance.Step 2. Check for correct outer ponton lock adjustment.Notify unit maintenance to check adjustment.END OF TESTING6. HANDRAIL STANCHION DOES NOT HOLD WHEN SETStep 1. Check handrail stanchion and support brackets for obstructions ordebris lodged at base. Free and remove debris from base of stanchion and supportbrackets.Step 2. Check for bent or broken support brackets, stanchion, or tensionspring.If brackets, stanchion, or spring appears damaged, notify unit maintenance.END OF TESTING