TM 5-5420-280-10
0006 00
COMMON BRIDGE TRANSPORTER (CBT) LOAD HANDLING SYSTEM (LHS)
CONTROLS AND INDICATORS (Contd)
O
RCU CABLE -- The power cable on hand-held RCU designed to connect to
LHS receptacle. The cable end with male cannon plug is connected to RCU
receptacle and secured by turning collar on cannon plug clockwise until tight.
P
EMERGENCY STOP SWITCH -- The EMERGENCY STOP toggle switch,
with guard, is located on control panel of hand-held remote control unit. When
pushed down, electrical power to RCU controls is shut off and all functions of
LHS stop.
Q
HIGH IDLE SWITCH -- The HIGH IDLE switch on the control panel of
RCU is placed in ON position to increase engine idle speed to 1,200 rpm for
LHS operation. The vehicle's PTO should be engaged prior to increasing
engine idle speed.
R
PANEL ILLUMINATION LIGHT -- The light on RCU that
illuminates
control panel for night operation.
S
WINCH SWITCH -- The WINCH toggle switch on control panel of RCU is
for winch operation. Hold switch in OUT position to pay-out winch cable, and
release switch to stop winch. Hold switch in IN position to pay-in winch cable,
and release switch to stop winch. The winch on REB pallet cannot be operated
by the LHS winch switch.
T
HOOK ARM SWITCH -- The HOOK ARM toggle switch on control panel of
RCU operates LHS hook harm. Hold switch in UNLOAD position to move
hook arm up and toward the rear of vehicle for unloading operations. Release
switch to stop hook arm. Hold switch in LOAD position to move hook arm
down and in a forward direction when performing loading operations. Release
switch to stop hook arm.
U
MAIN FRAME SWITCH -- The MAIN FRAME switch on control panel of
RCU operates LHS main frame. Hold switch in UNLOAD position to move
main frame up and toward the rear of vehicle for unloading operations.
Release switch to stop main frame. Hold switch in LOAD position to move
main frame down and toward front of vehicle when performing loading
operations. Release switch to stop main frame.
V
LHS RECEPTACLES -- There is an LHS
receptacle located on
each side of
main manifold support frame for operation of RCU from either side of vehicle.
The female cannon plug at the opposite end of RCU cable is connected to
either LHS receptacle, and is secured by turning collar on cannon plug
clockwise until tight.
0006 00-6