TM 5-5420-280-10
0046 00
GENERAL MAINTENANCE (Contd)
CLEANING (Contd)
WARNING
Skysol 100 cleaning solvent is combustible. Use mechanical
ventilation whenever product is used in a confined space, is
heated above ambient temperatures, or is agitated. DO NOT
use or store near heat, sparks, flame, or other ignition sources.
Keep container sealed when not in use.
Contact with Skysol 100 cleaning solvent may cause skin
irritation. Use chemical resistant gloves. In case of skin
contact, remove any contaminated clothing and wash skin
thoroughly with soap and water. Wash contaminated clothing
before reuse. Eye contact may cause irritation, tearing or
blurring of vision, Use face shield or goggles when eye contact
may occur. In case of eye contact, flush eyes with large
amounts of water for at least fifteen (15) minutes or until
irritation subsides. Inhalation may cause irritation to upper
respiratory passages. DO NOT have food or drink in the
vicinity. Failure to comply may result in injury to personnel.
CAUTION
Before opening reservoir, ensure area around reservoir filler
cap is clean. Do not allow dirt, dust, or water to enter
reservoir. Failure to do this may cause damage to internal
components.
3. Oil and Grease Covered Surfaces. Using Skysol 100, clean oil and grease
from exterior surfaces of bridge prior to cleaning dirt, mud, and debris with soap
and water.
4. Oil Seals and Flexible Hoses.
CAUTION
Do not allow Skysol 100 to come in contact with seals or
flexible hoses. Failure to comply will result in damage to
parts.
Do not use power washer to clean external surfaces of RCU,
and avoid directly spraying at all other electrical components,
or damage to equipment may result.
5. External Surfaces. Clean all accessible external surfaces of pallet and
bridge with soap and water and rinse thoroughly. Use power wash pump when
6. Rusted Surfaces.
NOTE
All parts subject to rusting must be lightly oiled after cleaning
and prior to storage.
Remove all evidence of corrosion.
0046 00-2