TM 5-5420-280-23&P
0015 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (Contd)
Table 1. Preventive Maintenance Checks and Services for Pallet (Contd).
ITEM
ITEM TO
EQUIPMENT NOT
INTERVAL
PROCEDURE
NO.
CHECK/SERVICE
READY/AVAILABLE IF:
46
Annual
Flow divider (1),
a. Check flow divider and pressure regulators
a. Any damage, loose
pressure
for damage, loose mounting hardware, or
mounting hardware,
regulators (3), and
leaking lines.
or Class III leaks
noted.
b. Check solenoid for damaged electrical leads,
b. Any damage, loose
loose mounting hardware, and leaking
mounting hardware,
lines.
or Class III leaks
noted.
c. Repair or replace leaking lines, damaged,
loose, or missing hardware. Refer to
1
3
2
0015 00-28