• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Critical Crack Length.
BRIDGE AND PALLET CRACK DEFORMATION INSPECTION AND REPAIR - Continued

Special Tools List For Rapidly Emplaced Bridge (Reb) Page Navigation
  247    248    249    250    251  252  253    254    255    256    257  
img
TM 5-5420-280-23&P
0030 00
BRIDGE AND PALLET CRACK DEFORMATION INSPECTION AND REPAIR (Contd)
Table 4. Structural Components that ARE Allowed to be Welded by Field Level on Bridge.
WARNING
Welding repair of bridge structural components is not allowed at
field level. Attempting welding repair of damaged structural areas
without proper heat treating will compromise strength of bridge.
Failure to comply may result in failure of bridge, damage to
equipment, and possible injury or death to personnel.
TOP DECK
~
TOP DECK
~
TOP DECK
RAMP END
~
~
0030 00-5