TM 55-1945-205-10-4
0099 00 56
0099 00
END OF WORK PACKAGE
1
Every 100
Hours of
Operation
.1
Light Tower
1. Check all hinges, nuts, bolts
clamps, rivets and latches
for looseness. If loose hinges, nuts,
bolts clamps, rivets or latches are
found, contact unit maintenance.
2. Check all enclosure panels for
warping, bending and tearing and
for positive sealing. If warping,
bending, tearing or defective seals
are found, contact unit maintenance.
2
Every 100
Hours of
Operation
.1
Light Tower Engine Check engine intake and exhaust
systems for loose, damaged or
deteriorated components. If loose,
damaged or deteriorated
components are found, contact unit
maintenance.
2
Every 150
Hours of
Operation
.2
Light Tower Engine Check air intake hoses
for damage. If hoses are damaged,
contact unit maintenance.
1
Every 250
Hours of
Operation
.5
Light Tower
Check radiator and oil cooler.
Ensure unrestricted airflow is
maintained through radiator and oil
cooler. If airflow is restricted, clean
radiator or oil cooler.
2
Every 250
Hours of
Operation
.3
Light Tower Engine Check all components of the cooling
system. Ensure unrestricted airflow
is maintained through radiator and
oil cooler.
3
6 Years
1.0
Generator Container Hydrostatically test portable fire
extinguisher and replace o-rings.
Contact Specialized Repair Activity
(SRA).
4
6 Years
1.0
Personnel Shelter
Hydrostatically test portable fire
extinguisher and replace o-rings.
Contact Specialized Repair Activity
(SRA).
Table 1. Preventive Maintenance Checks and Services. (Continued)
ITEM
NO.
INTERVAL
MAN-
HOURS
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF: