TM 55-1945-205-24-20052 00 50052 005.Remove all plastic and tape installed to seal out water and solvents.6.Start engine and run until normal operating temperature is reached.7.Clean the generator control box. WARNINGThe following steps should only be performed in a well ventilated area. Failure to do so could result in serious injury or death to personnel.a.Disconnect the battery cables at the light tower battery.b.Open the top of the generator control box and vacuum interior.NOTEThe cleaner must have an evaporative carrier agent which leaves no residue after application.c.Spray all switch contacts with a quality commercial electrical contact cleaner. d.Cycle the switches through all possible positions spraying at each position.e.Leave control box open until completely dry.f.Close the top of the generator control box.g.Connect battery cables.Rigid Hull Inflatable Boat And Motor CleaningWARNING1.Clean the hull with clean water and soap.