GENERATOR CONTAINER FUEL TANK CONTROL FUSE - TM-55-1945-205-24-2_245
INSTALL GENERATOR CONTAINER 1,000 GALLON FUEL TANK FUEL LEVEL SENSORS - TM-55-1945-205-24-2_248
TM-55-1945-205-24-2 Modular Causeway System (MCS) Roll-On/Roll-Off Discharge Facility Model (RRDF) RRDF-1 NSN 1945-01-473-2282 Manual
Page Navigation
179
180
181
182
183
184
185
186
187
188
189
TM 55-1945-205-24-2
0074 00 1
0074 00
UNIT LEVEL MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
GENERATOR CONTAINER 1,000 GALLON FUEL TANK FUEL LEVEL SENSORS
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanic’s (Rail and Marine) (Item 82, WP 0359 00)
Personnel Required
Engineer 88L
Equipment Condition
Generator
Shut Down. (TM 9-6115-642-10, TM 9-6115-643-10)
REMOVE
GENERATOR
CONTAINER 1,000 GALLON FUEL TANK FUEL LEVEL SENSORS
NOTE
The following procedure is typical for the removal and installation of all fuel level sensors.
1.
Remove nut (1) from elbow (2).
2.
Remove elbow (2) from sensor (3).
3
2
1