TM 55-1945-205-24-20077 00 3/4 blank 0077 00INSTALL GENERATOR CONTAINER 1,000 GALLON FUEL TANK MANUAL FUEL PUMP1Position new screen (6), new inlet gasket (5) and fuel pump (1) on inlet flange (4).2.Install four hex head screws (3) in inlet flange (4) and tighten. WARNING3.Apply sealing compound to male threads on pump (1).4.Connect hose (2) to pump (1).5.Inspect for leaks.a.Rotate pump handle (7) clockwise.b.Tighten connections as required.WARNING6.Clean up spilled fluid with a spill kit and dispose of spill kit waste in accordance with local procedures.END OF WORK PACKAGE