TM 55-1945-205-24-20182 00 10182 00UNIT LEVEL MAINTENANCEROLL-ON/ROLL-OFF DISCHARGE FACILITYLIGHT TOWER ENGINE FAN BELT GUARDREPLACEMENTINITIAL SETUP:ToolsTool Kit, General Mechanic’s (Rail and Marine) (Item 82, WP 0359 00)Gloves, Men’s and Women’s (Leather Palm) (Item 27, WP 0359 00)Goggles, Sun, Wind and Dust (Safety) (Item 29, WP 0359 00)Helmet, Safety (Brown) (Item 33, WP 0359 00)Life Preserver, Vest (Item 38, WP 0359 00)Materials/PartsGuard, Fan(33968)PN 36868727Personnel RequiredEngineer 88LEquipment ConditionLight Tower Battery Negative Lead Terminal Removed. (WP 0134 00)REMOVE LIGHT TOWER ENGINE FAN BELT GUARDWARNINGAll personnel must wear personal flotation device, hard hat, safety shoes and gloves during RRDF operations and maintenance. Failure to observe these precautions could result in injury or death.1.Remove two bolts (1) and hex nut (2) securing fan belt guard mounting bracket (3) to fan belt guard (4) and fan shroud (5).