TM 55-1945-205-24-20186 00 20186 00NOTERepair is limited to the replacement of defective piece parts.1.Remove the water pump flange (1) from water pump shaft (2).2.Remove water pump shaft (2) from water pump housing (3) with impeller (4) and mechanical seal (5) attached.3.Remove water pump impeller (4) from water pump shaft (2).4.Remove mechanical seal (5) from water pump shaft (2).5.Remove water return pipe (6) from water pump housing (3).CLEAN LIGHT TOWER ENGINE WATER PUMPWARNING1.Using wiping rags soaked with cleaner, remove debris from external components.WARNING2.Using wiping rags soaked with cleaner, remove debris from internal components.136254
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business