TM 55-1945-205-24-2
0206 00 1
0206 00
UNIT LEVEL MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
LIGHT TOWER DRAWBAR
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanic’s (Rail and Marine) (Item 82, WP 0359 00)
Gloves, Men’s and Women’s (Leather Palm) (Item 27, WP 0359 00)
Goggles, Sun, Wind and Dust (Safety) (Item 29, WP 0359 00)
Helmet, Safety (Brown) (Item 33, WP 0359 00)
Life Preserver, Vest (Item 38, WP 0359 00)
Materials/Parts
Drawbar
(33968)
PN 43210343
Block, Shoring (Item 6, WP 0358 00)
Qty 2
Personnel Required
Seaman 88K
Equipment Condition
Light Tower Drawbar Pintle And Bracket Removed. (WP 0200 00)
Light Tower Drawbar Chain/Hook Assembly Removed. (WP 0204 00)
Light Tower Drawbar Jack Removed. (WP 0203 00)
Light Tower Raise/Lower Winch Cable Removed. (WP 0201 00)
Light Tower Raise/Lower Winch Removed. (WP 0202 00)
REMOVE LIGHT TOWER DRAWBAR
WARNING
All personnel must wear personal flotation device, hard hat, safety shoes and gloves
during RRDF operations and maintenance. Failure to observe these precautions
could result in serious injury or death.
1.
Place a block of wood under the forward light tower structure frame to support light tower.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business