TM 55-1945-205-24-2
0215 00 1
0215 00
DIRECT SUPPORT MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
LIGHT TOWER - TOWER ELECTRICAL CABLE SHROUD
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanic’s (Item 81, WP 0359 00)
Gloves, Men’s and Women’s (Leather Palm) (Item 27, WP 0359 00)
Goggles, Sun, Wind and Dust (Safety) (Item 29, WP 0359 00)
Helmet, Safety (Brown) (Item 33, WP 0359 00)
Life Preserver, Vest (Item 38, WP 0359 00)
Materials/Parts
Shroud, Cable
(33968)
PN 36785822
Personnel Required
Engineer 88L
Equipment Condition
Telescopic Light Tower Assembly Lowered. (TM 55-1945-205-10-2)
REMOVE LIGHT TOWER - TOWER ELECTRICAL CABLE SHROUD
WARNING
All personnel must wear personal flotation device, hard hat, safety shoes and gloves
during RRDF operations and maintenance. Failure to observe these precautions
could result in serious injury or death.
1.
Loosen outer stuffing tube coupling (1) until
junction box
electrical cable (2) can be slid off notch in shroud (3).