TM 55-1945-205-24-20242 00 30242 00WARNING9.Tilt end of tube (11) and drain hydraulic fluid into drain pan.10. Remove hydraulic metal tube (11) and discard.WARNING11. Remove drain pan and dispose of hydraulic fluid in accordance with local procedures.INSTALL LIFT HYDRAULIC METAL TUBE FROM LIFT HYDRAULIC PUMP TO BULKHEAD ADAPTOR1.Using cloth, wipe fittings.2.Position new tube (11) on bulkhead adaptor (10). 3.Connect fitting (9) to bulkhead adaptor (10). Tighten fitting (9).4.Install three mounting clamps (7) on tube (11).5.Position three mounting clamps (7) on mounting bosses (8).6.Install three bolts (6), lock washers (5) and nuts (4) in mounting clamps (7). Tighten bolts (6).7.Connect fitting (3) to hydraulic pump (1). Tighten fitting (3).8.Rotate release valve (2) clockwise.9.Service EASY container hydraulic system. (WP 0233 00)WARNING10. Pump handle (12) until lift table (13) is fully elevated.11. Rotate relief valve (2) counterclockwise.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business