TM 55-1945-205-24-40042 00 10042 00UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCEFLOATING CAUSEWAYGENERATOR CONTAINERTROUBLESHOOTING PROCEDURESINITIAL SETUP:Test EquipmentMultimeter (Item 31, WP 0253 00)Personnel RequiredEngineer 88LReferencesTM 55-1945-205-10-4TROUBLESHOOTING PROCEDUREDC LIGHTS WILL NOT OPERATESYMPTOMDC lights will not illuminate.MALFUNCTIONLight bulb(s) burned out.CORRECTIVE ACTIONReplace light bulb(s). (WP 0086 00)Perform operational check on DC lighting. (TM 55-1945-205-10-4)MALFUNCTIONBroken or loose connectors in the DC wiring system.CORRECTIVE ACTIONTighten or replace connectors as necessary.Perform operational check on DC lighting. (TM 55-1945-205-10-4)MALFUNCTIONDC power source battery appears to be low or discharged.CORRECTIVE ACTIONReplace battery. (WP 0069 00)Perform operational check on DC lighting. (TM 55-1945-205-10-4)