CAPILLARY TUBE AND STRAINER
INSTALL PERSONNEL SHELTER THERMOSTAT
TM-55-1945-205-24-4 Modular Causeway System (MCS) Floating Causeway FC-1 NSN 1945-01-473-2162 Manual
Page Navigation
239
240
241
242
243
244
245
246
247
248
249
TM 55-1945-205-24-4
0104 00 1
0104 00
DIRECT SUPPORT MAINTENANCE
FLOATING CAUSEWAY
PERSONNEL SHELTER THERMOSTAT
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanic’s (Item 53, WP 0253 00)
Level, Spirit (Item 24, WP 0253 00)
Materials/Parts
Switch, Thermostatic
(10855)
NSN 5930-01-411-9735
PN HH01AD045
Personnel Required
Engineer 88L
References
TM 55-1945-205-10-4
REMOVE PERSONNEL SHELTER THERMOSTAT
1.
Position
circuit breaker
A (1) on the electrical distribution panel board to OFF.
2.
Remove cover (2) and discard.
1
CKT A
HEAT PUMP
208VAC, 1PH, 60MHZ
FDR (SHLTR PNL)-2P-A
2
3
4