TM 5-1940-322-24
0129 00
HYDROJET HATCH COVER, HINGES, AND SUPPORT BRACE MAINTENANCE (Contd)
REMOVAL
1.
Remove hook (13) from hole (16) in hydrojet hatch cover (1).
NOTE
Assistant will help with steps 2 and 3.
2.
Remove support brace (6) from slot (3) on hydrojet hatch cover (1).
3.
Remove two locknuts (8), four washers (4), two screws (10), and hydrojet hatch cover (1) from
hinges (11). Discard locknuts (8).
4.
Remove eight locknuts (8), sixteen washers (4), eight screws (15), and two hinges (14) from hydrojet
hatch cover (1). Discard locknuts (8).
5.
Remove eight locknuts (8), sixteen washers (4), eight screws (12), and two hinges (11) from hull (7).
Discard locknuts (8).
6.
Remove locknuts (8), two washers (4), screw (5), and chain (9) from support brace (6). Discard
locknut (8).
7.
Remove locknut (8), three washers (4), screw (5), and support brace (6) from hull (7). Discard
locknut (8).
CLEANING AND INSPECTION
1.
For general cleaning and inspection instructions, refer to WP 0013 00.
WARNING
Skysol 100 solvent is combustible; DO NOT use or store near heat,
sparks, flame, or other ignition sources. Use mechanical ventilation
whenever product is used in a confined space, heated above
ambient temperatures, or agitated. Keep container sealed when not
in use.
Contact with Skysol 100 may cause skin irritation. Use chemical-
resistant gloves. In case of skin contact, remove any contaminated
clothing and wash skin thoroughly with soap and water. Wash
contaminated clothing before reuse. Eye contact may cause
irritation, tearing, or blurring of vision. Use face shield or goggles
when eye contact may occur. In case of eye contact, flush eyes with
large amounts of water for at least 15 minutes or until irritation
subsides. Inhalation may cause irritation to upper respiratory
passages. DO NOT have food or drink in the vicinity. Failure to
comply may result in injury to personnel.
2.
Inspect seals (2) for damage. If missing or damaged, clean area with Skysol 100, dry with cloth, and
replace seals (2).
0129 00-2