TM 5-5420-202-20-3
DUST DETECTOR OPERATIONAL TEST (Sheet 1 of 3)
TOOLS:
1/2 in. combination box and open end wrench
SPECIAL TOOLS: Ground hop kit (Item 31, Chapter 3, Section I) if powerplant is out of tank
NOTE
Operational test may be performed with powerplant out
of vehicle if ground hop kit has starter cable modified
t o accommodate improved clean air system. If
powerplant is out of vehicle, connect ground hop kit
according to pocedures on page 5-27.
Operational test is the same for both right and left
sides.
1.
Remove dust and dirt from filter strip cover (A) and compressor housing (B).
2.
Using wrench, remove three screws (C) securing filter strip cover (A) to compressor
housing (B), but do not remove cover (A).
3.
Insert 1-inch wide strip of nonporous material (plastic, celluloid, etc.) over filter strip (D).
4.
Using wrench, tighten three screws (C).
Go on to Sheet 2