TM 5-5420-280-10
0043 00
Preventive Maintenance Checks and Services (PMCS) for Pallet (Contd).
NOT FULLY
ITEM
ITEM TO
MISSION
INTERVAL
PROCEDURE
NO.
CHECK/SERVICE
CAPABLE IF:
27
Before
RCU stowage
a. Check RCU stowage box for damaged
a. Latch or hinges
box (6),
latch, cover hinges, O-ring seal, or loose
missing.
electrical
or missing hardware.
harness (3),
NOTE
emergency stop
Turn on main power switch to verify
button (5) and
emergency stop button functions.
RCU (4)
Ensure emergency stop buttons on
electrical system box lid and RCU
storage box lid are in ON position.
b. Actuate emergency stop button on
b. Any emergency
RCU stowage box lid and electrical box
stop button is
lid.
inoperable.
c. Remove and check electrical harness
c. Electrical harness
for damage or loose connector.
damaged.
d. Check RCU for damaged display or
d. RCU damaged.
controls.
3
4
6
5
28
Before
Telescopic
a. Check telescopic tube for cracks or
a. Any cracks or
tube (11),
damage.
damage is noted.
rollers (7),
hydraulic
cylinder (9),
b. Check for loose or missing rollers.
b. Any loose or
lines (8), and
missing rollers.
hoses (10)
c. Any damage or
c. Check hydraulic cylinder, lines,
Class III leaks
fittings, and hoses for damage or leaks.
noted.
8
7
11
10
9
0043 00-15