TM 55-1945-205-10-2 0023 00 8 0023 00 2. Rotate lamp(s) (30) to desired position. 3. Tighten bolt (38) and nut (39). 4. Repeat adjustment until aiming of light is satisfactory. RAISE TOWER :,1* Do not operate tower with damaged cables. Damaged cables must be replaced as they may break during tower operation allowing the tower to fall. A falling tower could cause injury or death. Extend, retract or use in vertical position only. Ensure pin locks securely. Falling tower can cause severe injury or death. Ensure no overhead obstruction within 40 ft. Injury to personnel could occur. 1. Operate winch (40) to raise tower. 2. Insert and lock pin (41) to secure tower in upright position. EXTEND TOWER FOR UPRIGHT OPERATION 127( Do not extend mast tower past upright mark on tower. 1. With tower in upright position, operate winch (42) to extend tower to 28 ft above collar. Do not extend past upright mark on tower. 2. Loosen eye bolt (43) to rotate tower to desired position. 3. Tighten eye bolt (43). END OF WORK PACKAGE 42 43 41 40