TM 5-1940-322-24
0010 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) INTRODUCTION (Contd)
GENERAL SERVICE AND INSPECTION PROCEDURES (Contd)
WARNING
Skysol 100 solvent is combustible; DO NOT use or store near
heat, sparks, flame, or other ignition sources. Use mechanical
ventilation whenever product is used in a confined space, heated
above ambient temperatures, or agitated. Keep container sealed
when not in use.
Contact with Skysol 100 may cause skin irritation. Use chemical-
resistant gloves. In case of skin contact, remove any contaminated
clothing and wash skin thoroughly with soap and water. Wash
contaminated clothing before reuse. Eye contact may cause
irritation, tearing, or blurring of vision. Use face shield or goggles
when eye contact may occur. In case of eye contact, flush eyes with
large amounts of water for at least 15 minutes or until irritation
subsides. Inhalation may cause irritation to upper respiratory
passages. DO NOT have food or drink in the vicinity. Failure to
comply may result in injury to personnel.
7.
Use Skysol 100 to clean grease or oil from metal parts. After the item is cleaned, rinsed, and dried,
apply a light grade of oil to unprotected surfaces to prevent rusting. Use soap and water to clean
rubber and plastic materials.
END OF WORK PACKAGE
0010 00-2