TM 5-1940-322-24
0074 00
INTERMEDIATE FUEL SHUTOFF VALVE MAINTENANCE (Contd)
WARNING
Diesel fuel is flammable. Keep fuel away from open flames and
keep fire extinguisher within reach when working with fuel. Do not
work on fuel system while engine is hot. Fuel can be ignited by
contact with hot engine. Failure to comply may result in death or
injury to personnel.
CAUTION
Cap or plug all hoses, connections, and openings immediately after
disconnection to prevent contamination. Remove caps or plugs prior
to installation. Failure to comply may result in damage to
equipment.
NOTE
There are two intermediate fuel shutoff valves. Both fuel shutoff
valves are replaced the same way. This procedure covers the
replacement of one intermediate fuel shutoff valve.
Have container ready to catch fuel.
REMOVAL
1.
Turn handle (1) to closed position on fuel master shutoff valve (2).
2.
Loosen nut (4) and remove fuel line (3) from adapter (5).
3.
Loosen nut (9) and remove fuel line (10) from adapter (8).
4.
Remove adapter (5) and fuel shutoff valve (7) from bulkhead (6).
5.
Remove adapter (8) from fuel shutoff valve (7).
CLEANING AND INSPECTION
1.
For general cleaning and inspection instructions, refer to WP 0013 00.
WARNING
Skysol 100 solvent is combustible; DO NOT use or store near heat,
sparks, flame, or other ignition sources. Use mechanical ventilation
whenever product is used in a confined space, heated above
ambient temperatures, or agitated. Keep container sealed when not
in use.
Contact with Skysol 100 may cause skin irritation. Use chemical-
resistant gloves. In case of skin contact, remove any contaminated
clothing and wash skin thoroughly with soap and water. Wash
contaminated clothing before reuse. Eye contact may cause
irritation, tearing, or blurring of vision. Use face shield or goggles
when eye contact may occur. In case of eye contact, flush eyes with
large amounts of water for at least 15 minutes or until irritation
subsides. Inhalation may cause irritation to upper respiratory
passages. DO NOT have food or drink in the vicinity. Failure to
comply may result in injury to personnel.
2.
Clean excess sealing compound from adapters (8) and (5) with Skysol 100 and dry with cloth.
0074 00-2