TM 5-1940-322-24
0074 00
INTERMEDIATE FUEL SHUTOFF VALVE MAINTENANCE (Contd)
INSTALLATION
1.
Apply thin coat of sealing compound to adapters (8) and (5).
2.
Install adapter (8) on fuel shutoff valve (7).
3.
Secure fuel shutoff valve (7) on bulkhead (6) with adapter (5).
4.
Connect fuel lines (10) and (3) to adapters (8) and (5). Tighten nuts (9) and (4).
5.
Turn handle (1) to open position on fuel master shutoff valve (2).
6.
7.
Start engine and check for leaks (TM 5-1940-322-10).
8.
Close engine hatches (TM 5-1940-322-10).
9.
Close battery hatch (TM 5-1940-322-10).
3
4
5
6
7
8
1
2
9
10
END OF WORK PACKAGE