TM 5-1940-322-24
0141 00
HYDROJET GRILL MAINTENANCE (Contd)
WARNING
Hydrojet grill must be supported during removal and installation.
Failure to comply may result in damage to equipment or injury to
personnel.
NOTE
Assistant will help with removal and installation.
REMOVAL
Support hydrojet grill (3) and remove four locknuts (5), washers (4), and hydrojet grill (3) from hydrojet
inlet housing (1). Discard locknuts (5).
INSPECTION
1.
For general cleaning and inspection instructions, refer to WP 0013 00.
WARNING
Skysol 100 solvent is combustible; DO NOT use or store near heat,
sparks, flame, or other ignition sources. Use mechanical ventilation
whenever product is used in a confined space, heated above
ambient temperatures, or agitated. Keep container sealed when not
in use.
Contact with Skysol 100 may cause skin irritation. Use chemical-
resistant gloves. In case of skin contact, remove any contaminated
clothing and wash skin thoroughly with soap and water. Wash
contaminated clothing before reuse. Eye contact may cause
irritation, tearing, or blurring of vision. Use face shield or goggles
when eye contact may occur. In case of eye contact, flush eyes with
large amounts of water for at least 15 minutes or until irritation
subsides. Inhalation may cause irritation to upper respiratory
passages. DO NOT have food or drink in the vicinity. Failure to
comply may result in injury to personnel.
2.
Inspect threads on studs (2). Replace studs (2) if damaged. If replacing studs, apply coat of sealing
compound (272) on studs prior to installation.
INSTALLATION
1.
Apply light coat of sealing compound (243) on threads of studs (2).
2.
Install hydrojet grill (3) on hydrojet inlet housing (1) with four washers (4) and new locknuts (5).
Tighten locknuts (5) to 4448 lb-ft (6065 Nm).
0141 00-2