TM5-2090-202-12&P
TM 2090-12&P/1A
3-12. TIE-DOWN CABLE ASSEMBLIES MAINTENANCE INSTRUCTIONS - Continued
LOCATION/ITEM
ACTION
REMARKS
CLEAN, INSPECT AND REPAIR - CONTINUED
3.
Wire rope (6 and 7)
a.
Inspect for: Wear,
breaks, fraying
b.
Replace cable assy
if wire rope (7)
shows any of these
defects.
c.
Replace wire rode
Cut wire rope to
(6) and swaging
9-inches
sleeve (9) if wire
rope (6) shows any
of these defects.
WARNING
Cleaning solvent, Federal Specification P-D-680, is toxic and
flammable. Use solvent only in a well-ventilated area. Avoid
prolonged breathing of solvent vapors. Keep solvent away from
open flame. Do not use in excessive amounts.
4.
Cable assembly (3)
a.
Remove dirt,
grease, etc. with
wire brush. Clean
cable assembly
using a medium
bristle brush and
cleaning solvent.
b.
Allow to Dry.
INSTALLATION
CAUTION
For rear cable assemblies only, ensure rear corner bracket is in
place on boat hull.
5.
Cable assembly (3)
Install cable assembly
into position.
6.
Quick release pin (1)
Install pin
7.
Turnbuckle (4)
Tighten