FIXED FIRE EXTINGUISHER SYSTEM
CHAPTER 3. HULL MAINTENANCE

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -1 Page Navigation
  40    41    42    43    44  45  46    47    48    49    50  
img
.
TM 5-5420-202-20-1
SYSTEMS OPERATION - Continued
ENGINE SMOKE GENERATING SYSTEM. Smoke generating system
provides a
smoke
screen  capability  t o i m p r o v e  combat  e f f e c t i v e n e s s .
S m o k e generating system is
controlled by a switch on master control panel, and receives power through air
c l e a n e r blower  motor  relay.
Fuel,  r e g u l a t e d b y t w o s o l e n o i d v a l v e s a t r e a r o f
p o w e r p l a n t , is provided to system  f r o m main fuel lines into right and left bank upper
exhaust  pipes  where  f u e l p a s s e s t h r o u g h  turbosupercharger  a n d finally exhausted
through exhaust tubes as dense, white smoke.