Preventive Maintenance Checks and Services for M60A1 AVLB Hull - Continued
Preventive Maintenance Checks and Services for M60A1 AVLB Hull - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -1 Page Navigation
  87    88    89    90    91  92  93    94    95    96    97  
img
TM 5-5420-202-20-1
P r e v e n t i v e Maintenance Checks and Services for M60A1 AVLB Hull-
Continued
Location
Not Fully Mission
Procedure
Item to
Interval
Item
Capable if:
Check/Service
No.
Open air cleaner door (page 7-97).
Air Cleaners (Left
35
Semiannual
Check that door cam arms are not
and Right Sides)
- Continued
bent, cracked, or missing.
Check that air cleaner door seal is
not hardened, damaged, missing, or
does not have indentations.
Check that screw holes are drilled
through and free of dirt or obstruc-
tions.
Check that sealing lip on housing is
not damaged. If housing sealing lip
is damaged, notify support mainte-
nance.
Remove filter.
Change 4
3-48