TM 5-5420-202-20-1
P r e v e n t i v e M a i n t e n a n c e C h e c k s and Services for M60A1 AVLB Hull-
Continued
Location
Not Fully Mission
Item to
Interval
Procedure
Item
Capable if:
Check/Service
No.
WARNING
When using compressed air, use effective chip guarding and personal
protective equipment (goggles/shield, gloves, etc.).
Air Cleaners (Left
35
Semiannual
Remove two inspection plugs. Using
and Right Sides)
- Continued
Section I), direct compressed air into
upper hole until air coming out of
lower hole is free of dirt.
Dust Ejector System (VEDES), per-
form the following
Remove manifold cover
(page 7-148.2).
Check that four clamps are not
loose, damaged, or missing.
Check that two hoses are not dam-
aged or loose.
Check that six mounting screws are
not loose or missing.
Check that manifold tube is not
damaged.
Install manifold cover (page 7-148.3).
3-47
Change 4