TM 5-5420-202-20-1
P r e v e n t i v e Maintenance Checks and Services for M60A1 AVLB Hull -
Continued
Location
Not Fully Mission
Procedure
Item to
Interval
Item
Capable if:
Check/Service
No.
Broken or dam-
Engine Mounts
51
Check for broken, bent, or damaged
Semiannual
aged mounts.
mount bracket.
(Left and Right
Sides)
Check for loose, missing, or broken
screws and nuts.
NOTE
Use torque wrench from the underside of the mount. Position mirror
under torque wrench to observe torque reading.
Using 0-600 lb-ft torque wrench,
check that screws and nuts are
tightened to at least 450 lb-ft
(610 Nm).
Check for cracks and damage to rub-
ber mount.
Check for bent or broken alinement
bracket.
3-91
Change 4