POWER TAKE-OFF DISCONNECT
POWERPLANT TESTS (GROUND HOP)

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -2 Page Navigation
  22    23    24    25    26  27  28    29    30    31    32  
img
TM 5-5420-202-20-2
POWER TAKE-OFF DISCONNECT (Sheet 2 of 2)
1.
Install tube (A) between two spiders
(B).
Using wrench, install eight screws (C)
2.
to tube (A). Tighten screws to 265 to
325 lb-in (30-36 NZm).
Install universal joint cover (TM 5-5420-
3.
228-24).
End of Task