REMOVAL:
1.
Using socket and wrench, remove 16 screws,
washers, and lockwashers (A).
2.
Pull cover (B) away from air cleaner housing
just far enough to reach connectors (C).
Disconnect four connectors (C) from two
3.
circuit breakers (D) on cover (B). Remove
cover (B) with circuit breakers (D).
Using screwdriver, remove four screws (E)
4.
and washers (F) securing two circuit breakers (D)
to cover (B).
Remove gasket (G) from cover (B). Throw
5.
gasket (G) away.