• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
AIR CLEANER (ARMORED) CENTRIFUGAL FAN COVER AND GASKET REPLACEMENT
AIR CLEANER (ARMORED) CENTRIFUGAL FAN COVER AND GASKET REPLACEMENT - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -2 Page Navigation
  284    285    286    287    288  289  290    291    292    293    294  
img
TM 5-5420-202-20-2
AIR CLEANER (ARMORED) CENTRIFUGAL FAN COVER AND GASKET REPLACEMENT (Sheet 2 of 3)
REMOVAL:
Using socket, remove 10 screws
1.
and lockwashers (A) securing cover (B).
2.
Place cover (B) on top of housing (C).
3.
Disconnect four electrical leads from
two circuit breakers (D) mounted to
underside of cover (B).
Remove cover (B) and gasket (E).
4.
Throw gasket away.
5.
Using screwdriver, remove four screws and lockwashers (F) securing two circuit breakers
to cover (B).
Go on to Sheet 3