AIR CLEANER (ARMORED) CENTRIFUGAL FAN REPLACEMENT - Continued
AIR CLEANER (ARMORED) CENTRIFUGAL FAN REPLACEMENT - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -2 Page Navigation
  295    296    297    298    299  300  301    302    303    304    305  
img
TM 5-5420-202-20-2
AIR CLEANER (ARMORED) CENTRIFUGAL FAN REPLACEMENT (Sheet 5 of 7)
Position centrifugal fan (E) into
4.
housing (with exhaust outlet of
blower facing exhaust elbows) onto
support.
Position strap (F) over centrifugal
5.
fan (E).
6. Install two screws and washers (G) to secure strap (F) to support.
Using socket with extension, tighten screws (G).
7.
Connect long lead (H) from centrifugal fan (E) to ground lead connector (J).
8.
Go on to Sheet 6