TM 5-5420-202-20-2
AIR CLEANER (ARMORED) CENTRIFUGAL FAN REPLACEMENT (Sheet 4 of 7)
2.
Inspect support for defects or damage. Replace or repair as necessary.
3.
Inspect condition of pad. If defective or deteriorating, replace.
Inspect jumper lead. Check condition of insulation, connectors, and for continuity.
4.
Replace as necessary.
Inspect all threaded holes for damage or defects. Repair as necessary.
5.
INSTALLATION:
Position pad (A) and support (B) into housing.
1.
2.
Coat threads of screw (C) with sealer and
install with washer (D) to secure support (B).
Using wrench, tighten screw (C).
3.
Go on to Sheet 5