TM 5-5420-202-20-2
FUEL INLET FLUID PRESSURE FILTER REPAIR (Sheet 2 of 2)
CLEANING AND INSPECTION:
1. Inspect for broken or cracked components. Replace as necessary.
WARNING
To prevent personal injury, wear
Dry cleaning solvent P-D-680 is toxic and flammable.
protective goggles and gloves and use only in a well-ventilated area. Avoid contact with skin
eye, and clothes and don't breathe vapors. Do not use near open flame or excessive heat. The
flash point for Type #1 Dry Cleaning Solvent is 100F (380C) and for Type # 2 is 1380 (50 0C).
If you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid.
If contact with eyes is made, wash your eyes with water and get medical aid immediately.
Clean filter bowl, element, and spring with dry cleaning solvent and cloth.
2.
WARNING
Compressed air used for cleaning purposes
will not exceed 30 psi. Use only with
effective chip guarding and personnel
protective equipment goggles/shield,
gloves, etc).
Blow low-pressure, compressed air through
3.
filter element to remove dirt particles.
Replace element if damaged.
ASSEMBLY:
1. Place new preformed packing (A) in position on filter bowl (B).
2. Place filter element and spring (C) in filter head (D).
3. Place filter bowl (B) and filter head (D) together.
4. Using wrench, screw together filter bowl (B) and
filter head (D).
End of Task
TA248368
7-244