TM
5-5420-202-20-2
MANIFOLD HEATER FUEL RETURN SOLENOID VALVE REPLACEMENT (Sheet 4 of 5)
INSTALLATION:
NOTE
Coat all male threads of fittings with sealing compound
before installation.
1.
Position bracket (A) in place on shroud.
2.
Using 1/2 inch wrench, socket, and extension,
install three screws (B) to secure bracket to
shroud.
Using 9/1 6 inch wrench, install elbow
3.
with nipple, check valve, and elbow (C)
Using 1/2 inch wrench, install coupling
4.
with elbow and tee (E) on solenoid valve (D).
Go on to Sheet 5
7-285