TM 5-5420-202-34 20-2
TM 5-5420-202-
FUEL TANK (RIGHT) REPLACEMENT (Sheet 4 of 15)
12.
Using 1/2 inch socket, remove screws
(S) holding fire extinguisher tube and
clamps to tank. Remove the tube
assembly (T) from tank.
13.
Disconnect electrical connector (U) from
capacitor housing (V).
14.
Using 7/16 inch socket, remove screws
and washers securing two cable clamps (W).
Position cable and clamps aside.
15.
Using 1-1/2 inch wrench and adjustable
wrench, disconnect fuel vent hose (X)
.
Go on to Sheet 5
74312 ge 3 an7-337
Chan Ch ge 5