TM 5-5420-202-20-3
GENERATOR AIR lNTAKE TUBE ASSEMBLY REPLACEMENT (Sheet 2 of 3)
3.
Using socket, remove two bolts (F), lockwashers (G), and flat washers (H).
4.
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable.
To prevent personal injury, wear
protective goggles and gloves and use only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes and don't breathe vapors. Do not use near open flame or excessive heat. The
flash point for Type #1 Dry Cleaning Solvent is 100F (38C) and for Type #2 is 138 (50C).
If you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid.
If contact with eyes is made, wash your eyes with water and get medical aid immediately.
INSPECTION:
1.
Using alcohol and rags, clean hose. Inspect for cracks and breaks.
2.
Using dry cleaning solvent, clean tube and mounting hardware.
Using rags, wipe tube and mounting hardware. Inspect for bends, breaks, and cracks.
3.
Replace parts as required if defective.
G O on to Sheet 3
TA248945
10-4