TM 5-5420-202-20-3
FRONT ACCESSORY HARNESS REPLACEMENT (Sheet 10 of 14)
8.
Connect two bulk head connectors (P) (page
5-3).
9.
Connect connector (Q), CKT 975, 975A, to
fixed fire extinguisher relay (M).
10.
Using 1-1/8 inch wrench, tighten connector (Q).
11.
Connect connectors (R) CKT 975, to circuit
breakers (S).
12.
Connect connectors (T) CKT 400, 459, to circuit
breakers (U).
P
13.
Connect connector (V), CKT 415, 415A and
415B to air cleaner blower relay (N). Using
spanner wrench, tighten connector (V).
Connect electrical lead (W) to blower relay lead
14.
(X).
Using spanner wrench, install five connectors (Y).
15.
Position five straps (Z) over wiring harness assembly (A).
16.
17.
Using 7/16-inch socket, install flat washers (AA), new lockwashers (AB), and screws (AC)
securing five straps (Z)
18.
Position strap (AD) over wiring harness assembly (A).
19.
Using 7/16-inch wrench, install screw (AE), new lockwashers (AF), and flat washer (AG) securing
strap (AD).
Go on to Sheet 11
Change 7
10-296.97