TM 5-5420-202-20-4
REAR DRAIN VALVE CONTROL LEVER ASSEMBLY REPLACEMENT (Sheet 3 of 4)
Using 5/16 inch wrench, remove two screws (P)
9.
10.
Pull control lever (N) out of slot in bracket (L).
11.
Pull shaft (K) and control lever (N) out of
bracket (L).
12.
Secure lever (N) in vise and using hammer
and 1/2 inch punch, drive shaft (K) from
lever (N).
CLEANING AND INSPECTION:
WARNING
Dry cleaning solvent P-D-680 is tixic and flammable. To prevent personal injury, wear
protective goggles and gloves and use only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes and don't breathe vapors. Do not use near open flame or excessive heat. The
flash point for Type #1 Dry Cleaning Solvent is 100F (38C) and for Type #2 is 138F (50C).
If you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid.
If contact with eyes is made, wash your-eyes with water and get medical aid immediately.
1.
Using dry cleaning solvent and rags, clean
all parts.
2.
Inspect parts for bends, cracks, or other defects. Replace defective parts.
INSTALLATION:
1.
Push shaft (A) through holes in bracket (B) and hole in control lever (C). Make sure control
lever (C) is not installed backwards.
2.
Push control lever (C) in slot in bracket (B).
3.
Line up holes in lever stop (D) and holes
in bracket (B).
4.
attaching lever stop (D) to bracket (B).