TM 5-5420-202-20-4
FIXED FIRE EXTINGUISHER CONTROL VALVE REPLACEMENT (Sheet 6 of 14)
Using diagonal cut ting pliers, remove
11.
lead seal (P).
Using fingers, remove wire from three
12.
screws (Q) and pin (R).
Using screwdriver, remove three screws
13.
(Q) and washers (S) securing cover (T)
to housing (U).
Remove cover (T) from housing (U).
14.
Using 3/32 inch allen wrench, remove
15.
two screws (V) from retainer (W).
Remove sheave (X) and retainer (W)
16.
from housing (U).
Remove cable (Y) from housing (U)
17.
through hole in plug (Z).
Using adjustable wrench, remove plug
18.
(Z) from housing (U).
TA248665
Go on to Sheet 7
20-7