SMOKE GENERATOR HULL WIRING HARNESS REPLACEMENT - Continued
SMOKE GENERATOR HULL WIRING HARNESS REPLACEMENT - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -4 Page Navigation
  223    224    225    226    227  228  229    230    231    232    233  
img
.
TM 5-5420-202-20-4
SMOKE GENERATOR HULL WIRING HARNESS REPLACEMENT (Sheet 4 of 5)
INSTALLATION:
2.
Connect smoke generator switch con-
nector (B) to wiring harness connector
(C).
Place clamp (D) on wiring harness (A).
3.
Manually install screw (E) through clamp
4.
(D) and support (F).
Install lockwasher and nut (G) on screw
5.
(E).
Using socket and 7/16 inch wrench,
6.
tighten screw (E).
7.
Connect wiring harness connector (H)
to lead connector (J).
8.
Manually connect connector (K) to air
cleaner blower motor relay (L).
Use spanner wrench to tighten connector
9.
(K).
10.
Connect connector (M) to wiring harness
connector (N).
TA248755
Go on to Sheet 5