SMOKE GENERATOR HULL WIRING HARNESS REPLACEMENT (Sheet 4 of 5)
INSTALLATION:
2.
nector (B) to wiring harness connector
(C).
Place clamp (D) on wiring harness (A).
3.
Manually install screw (E) through clamp
4.
(D) and support (F).
Install lockwasher and nut (G) on screw
5.
(E).
Using socket and 7/16 inch wrench,
6.
tighten screw (E).
7.
Connect wiring harness connector (H)
to lead connector (J).
8.
Manually connect connector (K) to air
cleaner blower motor relay (L).
Use spanner wrench to tighten connector
9.
(K).
10.
Connect connector (M) to wiring harness
connector (N).
TA248755