TM 5-5420-202-20-4
SMOKE GENERATOR INTERMEDIATE FUEL HOSE REPLACEMENT (Sheet 5 of 5)
Install three clamps (F) onto intermediate fuel hose (G).
5.
Position intermediate fuel hose (G) along top right side of engine and connect to output
6.
port of fuel shut-off valve (H) and elbow (B) in shroud.
Using 7/8 inch wrench, tighten hose connections.
7.
Using socket, install and tighten three assembled washer screws (J) to secure clamps
8.
(F) to engine.
WARNING
Do not activate smoke generator in a building or closed area or with personnel near.
CAUTION
Always be aware of wind direction and speed when using smoke generator.
9.
Run engine at 1600 rpm and activate smoke generator. Observe operation. Shut off
smoke generator. Shut down engine.
Check smoke generator lines for leaks. Correct as necessary.
10.
11.
Install engine shroud (page 9-31).
End of Task
TA248761
21-20