TM 5-5420-202-20-4
SMOKE GENERATOR FUEL SHUT-OFF VALVE REPLACEMENT (Sheet 3 of 4)
INSTALLATION:
Install new preformed packings (A) on
1.
two adapters (B).
Using 1-1/4 inch wrench to hold fuel
2.
shut-off valve (C), manually install
adapters (B) with preformed packings
(A) into ports of fuel shut-off valve.
U sing 1 inch wrench, tighten adapters. (B).
3.
Position assembled fuel shut-off valve (C) to mounting bracket (D) and install two screws
4.
(E) and new nuts (F).
Using 7/16 inch wrench to hold nuts (F), use 7/16 inch socket and tighten screws (E).
5.
TA248764
Go on to Sheet 4