FRONT ACCESSORY HARNESS REPLACEMENT (Sheet 10 of 14)
Connect two bulkhead connectors (P)
8.
9.
Connect connector (Q), CKT 975, 975A,
to fixed fire extinguisher relay (M).
10.
Using 1-1/8 inch wrench, tighten connector
(Q).
11.
Connect connectors (R) CKT 975, to
circuit breakers (S).
Connect connectors (T) CTK 400, 459,
12.
to circuit breakers (U).
13.
Connect connector (V), CKT 415, 415A
and 415B, to air cleaner blower relay
(N). Using spanner wrench, tighten
connector (V).
14.
Connect electrical lead (W) to blower
15.
Using spanner wrench, install five connectors (Y).
Position five straps (Z) over wiring harness assembly (A).
16.
17.
Using 7/16 inch socket, install flat washers (AA), lockwashers (AB), and screws (AC)
securing five straps (Z).
18.
Position strap (AD) over wiring harness assembly (A).
19.
Using 7/16 inch wrench, install screw (AE), lockwashers (AF), and flat washer (AG) securing
strap (AD).
Go on to Sheet 11