4-17. Floodlights. - Continued
b. Repair. (figure 4-2)
(1) Loosen three screws (1) and remove door (2).
(2) Remove four springs (3) and pull lamp (4) partially out of body (5).
(3) Tag and disconnect wiring from lamp (4) and remove.
(4) Remove two screws (6) and remove switch retainer (7).
(5) Remove two screws (8) and washers (9) and remove switch (10) and holder (11).
(6) Tag and remove wiring (12) from body (5).
(7) Remove two bolts (13), six washers (14), four spring washers (15), two washers (16), two spacers (17), two
lockwashers (18), and two nuts (19), and separate body (5) from bracket (20).
(8) Remove two grommets (21).
(9) Remove two connector adapters (22).
(10) Remove two grommets (23).
Dry cleaning solvent PD-680 used to clean parts is potentially dangerous to personnel and property.
Avoid repeated and prolonged skin contact. Do not use near open flame or excessive heat. Flash point
of solvent is 100-138° F (38-60 °C).
(11)
(12)
(13)
(14)
(15)
(16)
(17)
(18)
(19)
Clean all items, except wiring and grommets, with dry cleaning solvent, and dry thoroughly.
Inspect all items and replace all items that are cracked, torn or othenwise damaged.
Install two grommets (23).
Install two connector adapters (22).
Install two grommets (21).
Position body (5) in bracket (20) and secure with two bolts (13), six washers (14), four spring washers (15),
two washers (16), two spacers (17), two lockwashers (18), and two nuts (19).
Install holder (11), switch (10) and secure with two screws (8) and washers (9).
Install switch retainer (7) and secure with two screws (6).
Connect wiring as tagged to body (5).
4-38
TM 5-5420-209-12
WARNING