TM 5-5420-209-12
Table 2-12. Operator Preventive Maintenance Checks and Services (PMCS) for the Interior Bay cont.
Location
Interval
Item To be Inspected
Equipment Is Not
Item to
Procedure
Service/Check
Ready/Available If
57
Before
Bilge Plugs
Ensure plugs are secured with wire rope to
Any plug missing.
ponton.
Inspect rubber seal for cuts, elasticity and dry
rot.
Check handle operation.
58
Before
Lift Pockets and Ensure pin functions properly.
Quick Release
Inspect pin for cracks and broken strands on
Pin
retaining wire rope.
Inspect pockets for cracks and broken welds.
59
Before
Deck Surface
Inspect for punctures, cracks, tears, dents,
Any damage which
holes and broken welds.
allows water into bay
cavity.
Check condition of non-skid coating.
60
Before
Rope Cleats
Inspect for cracks, broken welds and severe
deformation.
61
Before
Handrail Posts
Inspect posts for cracks at support base,
Handrail posts and rope
and Rope
cracks/elongation of bolt slots, broken or
missing.
(Roadside Bow
deformed rope ring and frayed or stretched
Ponton)
rope.
62
During
Lower Lock
Inspect screw and threads for cracks, burrs,
Screw will not extend or
Drive
nicks and deformation.
retract drive pin properly.
Inspect trunions, and drive pin for cracks.
Cracks or broken welds
Inspect cover bumpers and supports for
noted.
broken welds and deformation.
63
During
Deck Surface
Inspect for punctures, cracks, tears, dents,
Any damage which
holes and broken welds.
allows water into bay
cavity.
Check condition of non-skid coating.
64
During
Connector
Inspect for cracks, broken welds, elongation
Cracks or broken welds
Receptacles
and deformation.
noted. Elongation or
deformation prevents
proper seating of
connector.
65
During
Roadway
Ensure connector is correct type.
Incorrect connector type.
Connectors
Inspect connector, eye bracket, set screws,
Any defect which
spring and spring pins for cracks and
prevents proper seating
deformation.
of connector.
66
During
Roadway
Inspect for ruptured seams, holes punctures
Any defect allowing
Surface
and cracked welds.
water into bay cavities.
2-41