Table 2-12. Operator Preventive Maintenance Checks and Services (PMCS) for the interior Bay cont.ItemNo.6768697071IntervalDuringDuringDuringDuringAfterLocationItem toService/CheckRoadwaySurface(CurbsidePonton)RoadwayConnectorsConnectorReceptaclesDeck SurfaceRibbon BridgeComponentsItem To be InspectedProcedureInspect for ruptured seams, holes puncturesand cracked welds.Ensure connector is correct type.Inspect connector, eye bracket, set screws,spring and spring pins for cracks anddeformation.Inspect for cracks, broken welds, elongationand deformation.Inspect for punctures, cracks, tears, dents,holes and broken welds.Check condition of non-skid coating.After operation, clean all dirt, mud, and debrisfrom ribbon bridge components and lubricatein accordance with LO 5-5420-209-12.Equipment Is NotReady/Available IfAny defect allowingwater into bay cavities.Incorrect connector type.Any defect whichprevents proper seatingof connector.Cracks or broken weldsnoted. Elongation ordeformation preventsproper seating ofconnector.Any damage whichallows water into baycavity.2-42TM 5-5420-209-12